로고

MR Kit
Surgical Kit

MR Kit

Biotem surgical kit set with excellent drilling function and convenient surgical procedure.

MR Kit Overview

Product

MR KIT COMPONENT
Lance drill
Lance drill
Lance drill
# MR KIT COMPONENT

Lance drill

  • High visibility during surgery with laser markings at 8, 10, 11.5, 13, and 15, measurements correspond to the length of MR implants.
  • The Lance Drill is for cortical bone only; however, it is possible to drilling up to marker depending upon the surgical situation.

1652924469605487.png

Straight Drill
Straight Drill
Straight Drill
# MR KIT COMPONENT

Straight Drill

  • High visibility during surgery with laser markings at 8, 10, 11.5, 13, and 15, measurements correspond to the length of MR implants.
  • The Lance Drill is for cortical bone only; however, it is possible to drilling up to marker depending upon the surgical situation.

1652924540276898.png

Torque driver
Torque driver
Torque driver
# MR KIT COMPONENT

Torque driver

  • Driver for the MR implant narrow ridge and provisional type
  • Connect by matching up the triangle marker with the cross section of the implant (as shown)

1652924608278900.png

Machine driver
Machine driver
Machine driver
# MR KIT COMPONENT

Machine driver

  • Driver for the MR implant narrow ridge and provisional type
  • Connect by matching up the triangle marker with the cross section of the implant (as shown)

165292466618081 (1).png

O-ring Abutment Torque driver
O-ring Abutment Torque driver
O-ring Abutment Torque driver
# MR KIT COMPONENT

O-ring Abutment Torque driver

  • Driver for MR implant denture
  • Connect by matching up the triangle marker with the cross section of the implant (as shown)


1652924729272019.png

O-ring Abutment Machine driver
O-ring Abutment Machine driver
O-ring Abutment Machine driver
# MR KIT COMPONENT

O-ring Abutment Machine driver

  • Driver for MR implant denture
  • Connect by matching up the triangle marker with the cross section of the implant (as shown)
  1. 1652924801621507.png

Gauge for MR Implant
Gauge for MR Implant
Gauge for MR Implant
# MR KIT COMPONENT

Gauge for MR Implant

  • Depth gauge : Left side: Measures drilling depth / Right side: Used to modify the MR Implant Provisional neck angle
  • Never modify the MR narrow ridge neck
  • Parallel pin is used to check the path after drilling

1652924930942405.png

Driver Separator
Driver Separator
Driver Separator
# MR KIT COMPONENT

Driver Separator

  • Use when the driver is wedged with the implant. Insert the driver separator into the opening on the driver, and lever the driver off the implant.

165292497876759.png